09 · Heat exchangers and heat exchange equipment. Karshi

Thermal equipment
in Karshi

Heat exchangers, heating coils, cooling coils, and thermal transfer equipment — supplied, installed, and integrated into your HVAC system by Aurum Prodest. We size every component for your heat transfer fluid, air volume, and temperature differential so the system performs at design conditions, not just on paper.

Karshi anchors southern Uzbekistan's oil, gas, and chemical cluster — environments where standard ventilation is unsafe and corrosion is constant. Aurum Prodest installs explosion-protected exhaust where zones require Ex-rated equipment, anti-corrosion coatings on duct and frames, and industrial comfort cooling for control rooms and admin blocks separate from process areas. We deliver full as-built packages for enterprise auditors and safety officers.

Equipment selection depends on whether your system uses water, glycol, steam, or refrigerant as the heat transfer medium. We match coil face area, row depth, and fin spacing to the required duty and available pressure drop in both air and fluid circuits.

  • Heat exchanger and coil sizing
  • Water and refrigerant circuit design
  • Equipment supply and delivery
Industrial enterprisesAdministrative buildingsOil & gas facilitiesOffices
Thermal equipment in Karshi Karshi · 09

By the numbers

12+ years on market
500+ projects delivered
50+ specialists
5yr warranty

About the service

Equipment selection depends on whether your system uses water, glycol, steam, or refrigerant as the heat transfer medium. We match coil face area, row depth, and fin spacing to the required duty and available pressure drop in both air and fluid circuits.

Water coils connect to boiler loops, chiller circuits, or district heating supplies. Refrigerant coils integrate with DX systems and heat pumps. Each connection is designed for proper flow distribution, venting, and future maintenance access.

Before start-up we perform hydraulic pressure tests, check for leaks at every joint and gasket, and insulate bare pipework to prevent condensation and energy loss. Coil banks are installed with adequate drainage slope for condensate removal.

Commissioning verifies that supply air temperatures meet specification across the operating range. We connect coils to air handling unit automation — enabling frost protection, staging, and temperature control sequences that protect equipment and maintain comfort.

Our experience in Karshi

Refinery and gas-processing neighborhoods demand rigorous zoning: spark-free fans in classified areas, grounded duct, and documentation that matches ATEX-style expectations even when projects follow local permitting paths. Our engineers walk plants with HSE staff before quoting.

Administrative and control buildings need positive pressure and filtration so dust and odors from process units do not infiltrate IT rooms. We install precision cooling for server cabinets and VRV comfort for open offices — electrically segregated from field equipment.

Karshi's summer heat still pushes +44°C; outdoor units for safe zones get high-ambient specs, while sheltered plant rooms use ducted AHUs with redundant fans where downtime is costly. Aurum Prodest holds SRO admission and qualified welder certificates for pressure and ventilation works.

Service areas in Karshi

  • Mirmiron
  • Mustaqillik Avenue
  • Shahrisabz road
  • Industrial south
  • Gas processing vicinity
  • Qarshi-Airag highway strip
  • Navbahor
  • Kasbi direction
  • Railway zone
  • New admin center

Why clients choose us in Karshi

  • Explosion-protected ventilation for hazardous zones
  • Anti-corrosion execution for chemical/industrial air
  • Control-room pressurization and filtration
  • Full as-built documentation for enterprise audit
  • SRO admission and certified engineering staff

What's included

  • 01 Heat exchanger and coil sizing
  • 02 Water and refrigerant circuit design
  • 03 Equipment supply and delivery
  • 04 Installation in AHUs and duct sections
  • 05 Piping, valving, and insulation
  • 06 Hydraulic pressure and leak testing
  • 07 Automation and control integration
  • 08 Scheduled maintenance and coil cleaning

How we work

  1. 01 Thermal duty and airflow calculation
  2. 02 Equipment specification and ordering
  3. 03 Delivery and mechanical installation
  4. 04 Piping connection and insulation
  5. 05 Pressure testing and commissioning
  6. 06 Performance verification and handover

Advantages

Experienced specialists
Work warranty
Certified equipment
Same-day site visit
Transparent pricing
In-house production

Questions about Karshi

Do you work with oil & gas facilities in Karshi?

Yes. We have delivered industrial ventilation in classified areas using Ex-marked fans and switches, grounded installations, and scope agreed with plant safety departments. Non-sparking maintenance access is planned from day one.

Can you provide as-built documentation?

Every industrial project includes equipment passports, test reports, marked-up drawings, and commissioning measurements — suitable for internal QA and external inspection.

How do you separate office AC from process ventilation?

Physically separate air systems — no shared ducts between safe offices and field buildings. Control rooms may get overpressure and dedicated filtration stages.

What cooling suits Karshi summers on plant periphery?

High-ambient condensers, shaded racks, and sometimes evaporative pre-cooling for makeup air on large halls — always sized with local design temperatures, not European defaults.

Do you hold permits for industrial construction work?

Aurum Prodest maintains SRO membership, engineer attestation, and welder qualifications required for ventilation and refrigeration piping on regulated sites.

Need a consultation in Karshi? We respond within 15 minutes. Engineer visit and site survey are free when you sign a contract.

Get a consultation